Level and phase relay with pump protection – RNF 101 TED

38.00 Without VAT

Level and Phase Relay
Supply: 400V AC

3 in stock

Shipping is only available for Continental Portugal Shipping and its respective Autonomous Regions: Azores and Madeira.

Product description

Level and phase relay with pump protection against lack of water, phase failure or inverted sequence of motor phases.
Adjustable sensitivity, according to the liquid conductivity: 〔4 – 43〕KΩ


Applications

  • Total pump protection against lack of water and lack of phase to the motor or reverse phase sequence
  • Sensitivity adjustment 4 – 43 KΩ (depending on the conductivity of the immersion liquid)

Operation

Power the relay (green led on – A.1)

The relay is normally armed, disarmed whenever one of the following occurs:

Water level below probe “I” (lower) – only resets after water level rises above probe “S” (upper), green led “N.A.” – high level.

Missing or partial dropping of one of the “R”, “S” or “T” phases – resets automatically when the phases have the correct amplitudes.

Sequence of phases “R”, “S”, “T” inverted (phase change) – resets automatically when the correct sequence is reset.

Note: The images shown may not correspond completely to the product described.

Additional information

Weight 220 g
Dimensions 11 × 8.5 × 5.9 cm
Sensitivity adjustable

4, 43] KΩ

Room temperature

[-10ºC, +55ºC]

Output relay

AC 8A-250V / 50Hz – 1250VA DC 5A-24 V (C.R.)

Power

AC (3 x 400V) / 50Hz

Phase Drop Tolerance

pre-set from factory – 15% of "t.n" – nominal current

Consumption

2VA (approx.)

Supply

230V AC, 400V AC

Fitting

11-pin base